- TYPE D’OBJET
- disc/multiple
- DATE
- 1960–1969
- NUMÉRO DE L’ARTEFACT
- 2002.0622.001
- FABRICANT
- Pemco Inc.
- MODÈLE
- Kay-Cross
- EMPLACEMENT
- Cleveland, Ohio, United States of America
Plus d’information
Renseignements généraux
- Nº de série
- 370-F
- Nº de partie
- 1
- Nombre total de parties
- 1
- Ou
- S/O
- Brevets
- S/O
- Description générale
- stainless steel, clear Pyrex glass, and red rubber ring seals
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 79,0 cm
- Largeur
- 28,5 cm
- Hauteur
- 25,5 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Technologie médicale
- Catégorie
- Matériel médical
- Sous-catégorie
- S/O
Fabricant
- Ou
- Pemco
- Pays
- United States of America
- État/province
- Ohio
- Ville
- Cleveland
Contexte
- Pays
- Canada
- État/province
- Ontario
- Période
- This unit used during the 1960s.
- Canada
-
This machine was used at the Toronto General Hospital in the 1960s, during open heart surgeries. It replaced the Heimbecker oxygenator, and was in turn replaced by membrane oxygenators in the 1970s. [Ref. 2] - Fonction
-
To remove carbon dioxide waste gases from the blood and infuse it with oxygen before circulating it back through the body. - Technique
-
Designed by Earle B. Kay and Frederick S. Cross, and used in open heart surgeries performed at St. Vincent's Charity hospital in Cleveland, Ohio. 1956+. It's design is based on the Bjork oxygenator (c. 1948) which was used experimentally in animal studies. Rotating in the venous blood fed into the oxygenator cylinder, the discs turned at speeds of up to 120 RPM. This created a thin film of blood on the discs within the oxygen rich cylinder, but no bubbling or foaming [of blood]. The oxygen-infused blood was then circulated back through the patient's body. This device, though effective, was heavy, difficult to sterilize, and required an enormous amount of time to prepare for use. It also required a large amount of venous blood to prime. It was replaced by alternate designs.[ Refs.4 & 5] For detailed technical information on component parts, please see 1962 Pemco catalogue entry for Oxygenator. - Notes sur la région
-
Inconnu
Détails
- Marques
- "PEMCO INC./ CLEVELAND, OHIO" and "SERIAL NO./ 370-F" incised in one exterior end plate. "NO. 1129 PEMCO INC. CLEVELAND, OHIO" incised in both spring-tensioned end rings. "PEMCO INC./ CLEVELAND, OHIO" and "KAY CROSS" incised in opposite end plate. UHN catalogue no. "994.1.23" printed by hand in black ink, below. Rectangular decal applied to glass cylinder reads " Pemco Inc.", with open hand motif.
- Manque
- One nut missing from horizontal supports flanking cylinder. [NB: Modern wing-nut fitted by CSTM staff, in order to improve stability.]
- Fini
- Bright silver metal (stainless steel) endpieces & supports; dull silver metal (stainless steel) discs inside clear Pyrex glass cylinder; red rubber ring seals at either end.
- Décoration
- S/O
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
Pemco Inc., Oxygénateur, vers 1960–1969, Numéro de l'artefact 2002.0622, Ingenium - Musées des sciences et de l'innovation du Canada, http://collection.ingeniumcanada.org/fr/id/2002.0622.001/
RÉTROACTION
Envoyer une question ou un commentaire sur cet artefact.