Control unit

Use this image

Can I reuse this image without permission? Yes

Object images on the Ingenium Collection’s portal have the following Creative Commons license:

Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)

ATTRIBUTE THIS IMAGE

Ingenium, 2009.0061.001
Permalink:

Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.

DOWNLOAD IMAGE

PURCHASE THIS IMAGE

This image is free for non-commercial use.

For commercial use, please consult our Reproduction Fees and contact us to purchase the image.

OBJECT TYPE
X-RAY
DATE
1961
ARTIFACT NUMBER
2009.0061.001
MANUFACTURER
Picker X-Ray Corp.
MODEL
G-500S
LOCATION
Cleveland, Ohio, United States of America

More Information


General Information

Serial #
298
Part Number
1
Total Parts
1
AKA
N/A
Patents
N/A
General Description
metal and synthetic components

Dimensions

Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.

Length
69.0 cm
Width
38.0 cm
Height
141.0 cm
Thickness
N/A
Weight
N/A
Diameter
N/A
Volume
N/A

Lexicon

Group
Medical Technology
Category
Radiology
Sub-Category
N/A

Manufacturer

AKA
Picker
Country
United States of America
State/Province
Ohio
City
Cleveland

Context

Country
Canada
State/Province
Saskatchewan
Period
This unit believed used c. 1962+; not used after 2005.
Canada
Weyburn Mental Hospital in Weyburn, SK opened its doors in 1921 and closed (as the Souris Valley Hospital) in 2005. From the 1940s to 1971 it took part in controversial treatments for mental illness including lobotomy and electro shock therapy. It was also famous for its pioneering experiments with LSD in the 1950s and 60s. Dr. Humphrey Osmond, who coined the term "psychedelic" performed several experiments with patients and university students. In its heyday, the Weyburn was a well-equipped, self-sufficient health facility. Some complained that it was even better equipped than the local hospital. This x-ray machine [system component] would have been the workhorse for the institution. It was still in use after the building shut down a few years ago. It does not have direct ties to the more controversial history at Weyburn, but in colour and design, mirrored the institutional interior of Weyburn. Much of the old equipment and supplies went to developing countries when the shut-down occurred and some went to the University of Regina theatrical department. [Ref. 1]
Function
To regulate dosage, time exposure, and activate x-ray camera shutter.
Technical
Control unit for a durable x-ray, fluoroscopic machine used for many purposes. It was part of a new generation of fluoroscopic technology following the invention of large image intensifiers in 1953. With these photomultiplier tubes, ordinary movie cameras could capture the moving pictures of the fluoroscopic images. Contrast agents such as barium would have been used to see bodily processes in real time. {ref. 1]
Area Notes
Unknown

Details

Markings
All controls, etc. labelled. "PICKER G-500S" printed on metal plate fixed to unit front. Metal plate fixed to lower front edge of casing reads "PICKER X-RAY CORPORATION/ WAITE MANUFACTURING DIVISION CLEVELAND, OHIO, U.S.A./ CAT. 827/ SER. 298/ CYCLES 60/ LINE V. 240/ SEC. P.K.V. 150/PHASE 1/ AMPS/ SEC. CONT. 0.10/ SEC. INTER. 500/ LINE N.L. 7/ LINE CONT. 15/ LINE INTER. 355". "WARNING/ THIS X-RAY EQUIPMENT IS DANGEROUS TO BOTH PATIENT AND OPERATOR UNLESS SAFE EXPOSURE FACTORS/ ARE OBSERVED. SOLD TO BE USED ONLY BY OR ON THE PRESCRIPTION OF A PHYSICIAN/ WARNING" printed on lower front of control panel. Green dymo label applied to casing below control panel reads "KEEP ROTOR ON AS SHORT AS POSSIBLE".
Missing
Unknown.
Finish
Metal cabinet painted drab green; silver/grey, black and opaque synthetic and metal trim and minor fittings; off-white and light grey synthetic coverings on electrical cables; light grey synthetic and silver metal hand grip [trigger] control.
Decoration
N/A

CITE THIS OBJECT

If you choose to share our information about this collection object, please cite:

Picker X-Ray Corp., Control unit, circa 1961, Artifact no. 2009.0061, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingeniumcanada.org/en/id/2009.0061.001/

FEEDBACK

Submit a question or comment about this artifact.

More Like This


...
Nameplate

2009.0062.002

Object

...
Cable

2009.0068.004

Object

...
Cable

2009.0068.005

Object

...
Cable

2009.0068.006

Object

...
X-ray machine…

2009.0068.002

Object

...
Restraint, ab…

2009.0062.004

Object

...
Rail

2009.0068.012

Object

...
Rail

2009.0068.013

Object

...
Rail

2009.0068.014

Object

...
Rail

2009.0068.009

Object

...
Rail

2009.0068.010

Object

...
Rail

2009.0068.011

Object

...
Mount, x-ray …

2009.0068.008

Object

...
Rail

2009.0068.015

Object

...
Rail

2009.0068.016

Object

...
Table, x-ray

2009.0062.001

Object

...
X-ray machine

2009.0068.001

Object

...
Plate, cover

2009.0068.007

Object

...
Cassette, x-r…

2009.0064.001

Object

...
Cassette, x-r…

2009.0065.001

Object

...
Cassette, x-r…

2009.0067.001

Object

...
Table, x-ray

2009.0063.001

Object

...
X-ray machine…

2009.0068.003

Object

...
Cassette, x-r…

2009.0066.001

Object

...
Carrier, x-ra…

2009.0062.003

Object

...
Carrier, x-ra…

2009.0063.002

Object

...
Tile

2009.0060.004

Object

...
Tile

2009.0060.005

Object

...
Tile

2009.0060.006

Object

...
Tile

2009.0060.007

Object

...
Tile

2009.0060.008

Object

...
Tile

2009.0060.009

Object

...
Tile

2009.0060.010

Object

...
Tile

2009.0060.011

Object

...
Tile

2009.0060.013

Object

...
Tile

2009.0060.014

Object

...
Tile

2009.0060.015

Object

...
Tile

2009.0060.016

Object

...
Tile

2009.0060.018

Object

...
Tile

2009.0060.019

Object

...
Tile

2009.0060.020

Object

...
Tile

2009.0060.021

Object

...
Tile

2009.0060.022

Object

...
Tile

2009.0060.023

Object

...
Tile

2009.0060.024

Object

...
Tile

2009.0060.025

Object

...
Tile

2009.0060.026

Object

...
Tile

2009.0060.027

Object

...
Tile

2009.0060.028

Object

...
Tile

2009.0060.029

Object

...
Tile

2009.0060.031

Object

...
Tile

2009.0060.032

Object

...
Tile

2009.0060.033

Object

...
Tile

2009.0060.034

Object

...
Tile

2009.0060.035

Object

...
Tile

2009.0060.036

Object

...
Tile

2009.0060.001

Object

...
Tile

2009.0060.002

Object

...
Tile

2009.0060.003

Object

...
Tile

2009.0060.012

Object

...
Tile

2009.0060.017

Object

...
Tile

2009.0060.030

Object

...
X-ray diffrac…

1984.0779.001

Object

...
Fluoroscope

1992.0579.001

Object

...
Control panel

1987.2152.001

Object

...
Fluoroscope

1983.0455.001

Object

...
Fluoroscope

2002.0555.001

Object

...
Respirator

1995.1012.001

Object

No image available.
Bracket

1972.0266.003

Object

No image available.
Bracket

1972.0266.004

Object

No image available.
Bracket

1972.0266.005

Object

...
Illuminator

1987.2156.001

Object

...
Apron, safety

1987.2146.001

Object

...
Holder, x-ray…

1981.0350.001

Object

...
Scanner, radi…

1982.0244.001

Object

...
X-ray machine

1975.0042.001

Object

...
Control unit

1969.1029.002

Object

...
Meter, radiat…

1998.0198.001

Object

...
Controller

1975.0042.003

Object

No image available.
Tent

1972.0266.002

Object

...
X-ray machine

1969.1029.001

Object

...
Holder, x-ray…

1984.1229.001

Object

...
Holder, x-ray…

1984.1229.002

Object

...
Gauge, oil, f…

2006.0137.002

Object

...
Respirator

1995.1011.001

Object

...
Dosimeter

2002.0771.002

Object

...
Holder, x-ray…

1975.0042.008

Object

...
Cone, X-ray

1969.1029.038

Object

...
Oscilloscope

1973.0434.001

Object

...
Oxygen machin…

1972.0266.001

Object

...
Transformer

1969.1029.003

Object

No image available.
Timer

1975.0042.002

Object

...
Source, stand…

1997.0795.008

Object

...
Timer

1997.0803.001

Object

...
Holder, x-ray…

1975.0042.004

Object

...
X-ray machine

1982.0234.001

Object

No image available.
Source, stand…

1997.0795.009

Object

No image available.
Source, stand…

1997.0795.010

Object

No image available.
Source, stand…

1997.0795.011

Object

No image available.
Source, stand…

1997.0795.012

Object