OBJECT TYPE
remote/resistance
DATE
1992
ARTIFACT NUMBER
2004.0319.001
MANUFACTURER
YSI Inc.
MODEL
YSI44212
LOCATION
Yellow Springs, Ohio, United States of America

More Information


General Information

Serial #
93K72542/ 20048
Part Number
1
Total Parts
3
AKA
N/A
Patents
N/A
General Description
metal sensor & wire/ synthetic wire covering

Dimensions

Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.

Length
92.0 cm
Width
N/A
Height
N/A
Thickness
N/A
Weight
N/A
Diameter
N/A
Volume
N/A

Lexicon

Group
Meteorology
Category
Atmospheric temperature measurement
Sub-Category
N/A

Manufacturer

AKA
YSI
Country
United States of America
State/Province
Ohio
City
Yellow Springs

Context

Country
Canada
State/Province
Unknown
Period
This instrument was apparently in use for twelve years (Ref. 6)
Canada
A temperature sensor of the type used by the Meteorological Service of Canada to gather temperarture and/or dewpoint data across Canada, probably typical of the installations at MAPS1 and IWD automatic station installations from about 1980 to the present (2004) [See Supp. Info. 2004.0318]. Part of a large collection of meteorological instruments acquired from the Meteorological Service of Canada (previously Atmospheric Environment Service) by the CSTM since 1967. MSC is the government agency responsible for collecting and disseminating meteorological data and forecasts in Canada. It was founded in 1871 in Toronto where it is still headquartered. The MSC was originally on the University of Toronto downtown campus but moved to Downsview in 1971 on land owned by UofT. The headquarters houses laboratories, research facilities and calibration and instrument maintenance facilities (now largely contracted out).
Function
The temperature sensing element of a remote temperature and/or dewpoint indicating system which provides ambient & dewpoint temperature measurements.
Technical
An example of a temperature sensing element used in a temperature reading unit or a remote temperature /dewpoint measuring system. The most commonly used temperature sensor in Canada is called a thermistor which is a mixture of metal oxide semiconductors prepared from finely powdered metal oxides. The resistance of these semiconductors changes exponentially with temperature and has a negative temperature coefficient. Over a 100°C range the thermistor resistance changes three orders of magnitude. The first Canadian use of thermistors for weather observations was on an automatic buoy in Lake Ontario during WWII. At automated stations in Canada an array of three thermistors and two precision resistors are potted in a metal probe to produce, with an external balancing resistor, a temperature sensor with a linear response. This is called a thermolinear array. The YSI 44212 thermistor array was selected in about 1980 for network use due to its high resistance (13.7 kW) which almost eliminates the effect of lead resistance in field installations. Also the output which was a linear with temperature did not require special circuits or computations to derive the temperature from the sensor resistance. YSI 44212 Thermolinear Array (Yellow Springs Incorporated) Range -50 to +50°C
Area Notes
Unknown

Details

Markings
Incised lettering reading '93K72542', '20048' and '62'
Missing
hardware to attach sensor to tower mount (.2)
Finish
plated sensor, white wire covering
Decoration
N/A

CITE THIS OBJECT

If you choose to share our information about this collection object, please cite:

YSI Inc., Sensor, temperature, circa 1992, Artifact no. 2004.0319, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingeniumcanada.org/en/id/2004.0319.001/

FEEDBACK

Submit a question or comment about this artifact.

More Like This


...
Sensor, tempe…

2009.0135.006

Object

...
Holder, therm…

2004.0319.002

Object

...
Sensor, tempe…

2004.0327.001

Object

...
Sensor, tempe…

1989.0116.001

Object

...
Thermistor

1989.0115.001

Object

...
Standard, tem…

2004.0369.001

Object

...
Indicator, te…

1987.0644.001

Object

...
Standard, tem…

2004.0370.001

Object

...
Psychrometer

1987.0874.001

Object

...
Hygrometer

2004.0318.001

Object

...
Standard resi…

2004.0372.004

Object

...
Sensor, tempe…

2004.0326.013

Object

...
Sensor, tempe…

2004.0326.014

Object

No image available.
Thermometer

2004.0372.012

Object

...
Indicator, te…

1987.0646.001

Object

...
Standard resi…

2004.0372.006

Object

...
Case, instrum…

2004.0326.016

Object

No image available.
Thermometer

2004.0373.006

Object

...
Standard resi…

2004.0372.001

Object

...
Standard resi…

2004.0372.002

Object

...
Standard resi…

2004.0372.003

Object

...
Standard resi…

2004.0372.005

Object

...
Standard resi…

2004.0373.001

Object

...
Standard resi…

2004.0373.002

Object

...
Standard resi…

2004.0373.003

Object

...
Standard, tem…

2004.0314.001

Object

...
Thermometer

2004.0372.007

Object

No image available.
Thermometer

2004.0372.008

Object

No image available.
Thermometer

2004.0372.009

Object

No image available.
Thermometer

2004.0372.010

Object

No image available.
Thermometer

2004.0372.011

Object

...
Thermometer

2004.0373.004

Object

No image available.
Thermometer

2004.0373.005

Object

...
Sensor, tempe…

1987.0651.001

Object

...
Resistor

2004.0376.001

Object

...
Sensor, snow

2004.0332.001

Object

...
Radiosonde

2009.0127.001

Object

...
Battery

2009.0127.002

Object

...
Radiosonde

2004.0361.001

Object

...
Thermometer

2004.0324.001

Object

...
Radiosonde

1991.0083.001

Object

...
Thermometer

2004.0322.001

Object

...
Thermometer

2004.0323.001

Object

...
Barograph

2004.0362.002

Object

...
Radiosonde

1991.0084.001

Object

...
Stand, thermo…

2004.0328.001

Object

...
Case, instrum…

2004.0326.015

Object

...
Bathythermogr…

2004.0317.001

Object

...
Thermometer

2004.0325.001

Object

...
Indicator, te…

1987.0648.001

Object

...
Rule

2004.0331.001

Object

...
Slide, meteor…

2009.0131.001

Object

...
Mount, anemom…

2004.0352.001

Object

...
Barograph

2004.0362.001

Object

...
Thermograph

1987.0650.001

Object

...
Radiosonde

2005.0041.001

Object

...
Rule

2004.0330.001

Object

...
Actinometer

2004.0343.001

Object

...
Barometer

2004.0365.001

Object

...
Sensor, moist…

1996.0499.002

Object

...
Standard, len…

2004.0371.001

Object

...
Thermograph

1987.0649.001

Object

No image available.
Radiosonde

1974.0092.002

Object

...
Hub, anemomet…

2009.0128.001

Object

...
Autostation, …

2009.0135.001

Object

...
Scale, sunshi…

2009.0130.001

Object

...
Radiosonde

1991.0097.001

Object

...
Map

2009.0134.001

Object

...
Map

2009.0134.002

Object

...
Map

2009.0134.003

Object

...
Map

2009.0134.004

Object

...
Thermometer

2004.0326.009

Object

...
Thermometer

2004.0326.010

Object

...
Thermometer

2004.0326.011

Object

...
Thermometer

2004.0326.002

Object

...
Thermometer

2004.0326.003

Object

...
Thermometer

2004.0326.004

Object

...
Thermometer

2004.0326.005

Object

...
Thermometer

2004.0326.001

Object

...
Thermometer

2004.0326.006

Object

...
Thermometer

2004.0326.007

Object

...
Thermometer

2004.0326.008

Object

...
Thermometer

2004.0326.012

Object

...
Radiosonde

1974.0091.001

Object

...
Gauge kit

2004.0381.001

Object

...
Actinograph

2004.0341.001

Object

...
Plate, inform…

2009.0132.001

Object

...
Radiosonde

1991.0087.001

Object

No image available.
Thermistor

1989.0116.002

Object

...
Barometer

2004.0366.001

Object

...
Radiosonde

1991.0099.001

Object

...
Radiosonde

1991.0091.001

Object

...
Pyrheliometer

2004.0347.001

Object

...
Pyranometer

2004.0338.001

Object

...
Graduate

2004.0329.001

Object

...
Hygrothermogr…

1988.0933.001

Object

...
Mount, radiom…

2004.0316.001

Object

...
Thermometer

1987.0702.001

Object

...
Conversion kit

2004.0382.001

Object

...
Manometer

2004.0363.001

Object