- OBJECT TYPE
- CIRCULAR/SPECIALTY/RADIOACTIVITY
- DATE
- 1949
- ARTIFACT NUMBER
- 1997.0798.001
- MANUFACTURER
- Nuclear-Chicago Corp.
- MODEL
- NUCLEARULE
- LOCATION
- Des Plaines, Illinois, United States of America
More Information
General Information
- Serial #
- N/A
- Part Number
- 1
- Total Parts
- 2
- AKA
- N/A
- Patents
- N/A
- General Description
- SYNTHETIC RULE AND CASE.
Dimensions
Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.
- Length
- N/A
- Width
- N/A
- Height
- N/A
- Thickness
- N/A
- Weight
- N/A
- Diameter
- 14.4 cm
- Volume
- N/A
Lexicon
- Group
- Physics
- Category
- Atomic & nuclear
- Sub-Category
- N/A
Manufacturer
- AKA
- Nuclear Chicago
- Country
- United States of America
- State/Province
- Illinois
- City
- Des Plaines
Context
- Country
- Canada
- State/Province
- Quebec
- Period
- THIS SLIDE RULE PRESUMABLY USED MID-1960S TO 1970S.
- Canada
-
USED IN MONTREAL, PQ MEDICAL PRACTICE OF DR. ROGER GHYS TO DETERMINE DOSAGE LEVELS FOR RADIATION AND BRACHYTHERAPY TREATMENTS, AND FOR TESTING THE STANDARDS OF HIS EQUIPMENT. - Function
-
USED TO CALCULATE FACTORS AFFECTING MEASUREMENTS OF RADIOACTIVITY. - Technical
-
USED TO CALCULATE COUNTS PER MINUTE, PROBABLE ERROR, COINCIDENCE LOSS, DECAY OF ACTIVITY, ETC. AS RELATED TO MEASUREMENTS OF RADIOACTIVITY. THESE CALCULATIONS ARE ROUTINELY MADE WHEN WORKING WITHSTANDARD RADIATION DETECTION INSTRUMENTS. - Area Notes
-
Unknown
Details
- Markings
- Markings on face include "ACTIVITY", "COUNTS/MINUTE", "NUMBER 1/2 LIVES", "COINCIDENCE LOSS (%)" and "RESOLUTION LOSS" scales, and "nuclearule/ [logo]/ NUCLEAR-CHICAGO/ INSTRUCTIONS/ 1. Set black arrow to COUNTS/MINUTE./ 2. Read COINCIDENCE LOSS opposite/ RESOLUTION TIME./ 3. For further uses and further information/ consult instruction manual./ Copyright 1949 Nuclear-Chicago Corp.". Marking on reverse include "REGISTER READING", "SCALE FACTOR", "PROBABILITY (%)", "FRACTIONAL ERROR (%)", "COUNTS PER MINUTE" and "TIME (Minutes)" scales, and "INSTRUCTIONS". Instructions printed on one side of slide rule appear as follows: "INSTRUCTIONS/ 1. Set SCALE FACTOR of scaler used opposite REGISTER/ READING./ 2. Read COUNTS PER MINUTE opposite TIME (minutes)./ If circle below is black, use small K's./ 3. Read FRACTIONAL ERROR corresponding to Probable Error, Standard Error, or Reliable Error./ Fro more details and further information consult instruction/ manual. ". "k CIRCLE" printed, below.
- Missing
- NONE.
- Finish
- WHITE AND OPAQUE SYNTHETIC CIRCULAR SLIDE RULE BEARS RED AND BLACK TEXT AND MARKINGS.
- Decoration
- N/A
CITE THIS OBJECT
If you choose to share our information about this collection object, please cite:
Nuclear-Chicago Corp., Slide rule, after 1949, Artifact no. 1997.0798, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingeniumcanada.org/en/item/1997.0798.001/
FEEDBACK
Submit a question or comment about this artifact.