Tonometer
Use this image
Can I reuse this image without permission? Yes
Object images on the Ingenium Collection’s portal have the following Creative Commons license:
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUTE THIS IMAGE
Ingenium,
2002.0462.001
Permalink:
Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.
DOWNLOAD IMAGEPURCHASE THIS IMAGE
This image is free for non-commercial use.
For commercial use, please consult our Reproduction Fees and contact us to purchase the image.
- OBJECT TYPE
- Ophthalmology/indentation/Schioetz
- DATE
- Unknown
- ARTIFACT NUMBER
- 2002.0462.001
- MANUFACTURER
- A J Co.
- MODEL
- Unknown
- LOCATION
- Unknown
More Information
General Information
- Serial #
- 2020
- Part Number
- 1
- Total Parts
- 5
- AKA
- N/A
- Patents
- N/A
- General Description
- metal
Dimensions
Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.
- Length
- 13.8 cm
- Width
- 4.4 cm
- Height
- 1.1 cm
- Thickness
- N/A
- Weight
- N/A
- Diameter
- N/A
- Volume
- N/A
Lexicon
- Group
- Medical Technology
- Category
- Instruments
- Sub-Category
- N/A
Manufacturer
- AKA
- AJ
- Country
- Unknown
- State/Province
- Unknown
- City
- Unknown
Context
- Country
- Canada
- State/Province
- Quebec
- Period
- Unknown
- Canada
-
Used by late Dr. A. Isserman, in Montreal PQ. - Function
-
Used to measure the intraocular pressure. - Technical
-
Indentation tonometer measures the amount of corneal indentation that occurs when a given weight is placed on the cornea. The result is inversely proportional to the intraocular pressure, and must be obtained from a table of values (missing). Schiotz tonometer is typically supplied with 5.5g weight (permanently fitted to instrument), 7.5 g weight (missing) and 10g weight, and value table (missing). Elevated intraocular pressure is a symptom of various medical disorders, including glaucoma. Designed by Hjalmar August Schiotz, and first demonstrated in 1905, the Schiotz tonometer was quickly adopted and used worldwide. Though still used in both human and veterinary practices (2005), it has largely been replaced by less invasive instruments, which do not employ direct contact with the cornea. (ref. 2) - Area Notes
-
Unknown
Details
- Markings
- Tonometer scale graduated 0 to 20, in single increments. "A J Co. 2020" stamped into scale back.
- Missing
- Tonometer is complete; however, instrument set missing 1 weight (7.5 g) and table of values.
- Finish
- Brushed and bright silver metal finishes; scale indicator needle has been blued.
- Decoration
- N/A
CITE THIS OBJECT
If you choose to share our information about this collection object, please cite:
A J Co., Tonometer, Unknown Date, Artifact no. 2002.0462, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingeniumcanada.org/en/item/2002.0462.001/
FEEDBACK
Submit a question or comment about this artifact.