Baromètre
Utiliser cette image
Puis-je réutiliser cette image sans autorisation? Oui
Les images sur le portail de la collection d’Ingenium ont la licence Creative Commons suivante :
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUER CETTE IMAGE
Ingenium,
2004.0366.001
Permalien:
Ingenium diffuse cette image sous le cadre de licence Creative Commons et encourage son téléchargement et sa réutilisation à des fins non commerciales. Veuillez mentionner Ingenium et citer le numéro de l’artefact.
TÉLÉCHARGER L’IMAGEACHETER CETTE IMAGE
Cette image peut être utilisée gratuitement pour des fins non commerciales.
Pour un usage commercial, veuillez consulter nos frais de reproduction et communiquer avec nous pour acheter l’image.
- TYPE D’OBJET
- aneroid/digital/pressure transducer/portable
- DATE
- 1971
- NUMÉRO DE L’ARTEFACT
- 2004.0366.001
- FABRICANT
- Bell & Howell
- MODÈLE
- 4-461-0005
- EMPLACEMENT
- Pasadena, California, United States of America
Plus d’information
Renseignements généraux
- Nº de série
- 2180
- Nº de partie
- 1
- Nombre total de parties
- 1
- Ou
- S/O
- Brevets
- S/O
- Description générale
- metal casing and parts/ synthetic front panel, synthetic controls, indicator window, power cord and parts/ paper chart taped to top/ leather? handle
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 33,0 cm
- Largeur
- 15,2 cm
- Hauteur
- 20,0 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Météorologie
- Catégorie
- Divers
- Sous-catégorie
- S/O
Fabricant
- Ou
- Bell Howell
- Pays
- United States of America
- État/province
- California
- Ville
- Pasadena
Contexte
- Pays
- Canada
- État/province
- Ontario
- Période
- 1960's - 1980's +
- Canada
-
An instrument used in the Calibration Unit of the Instrument Division of the Meteorological Branch of the Department of Transport of the Government of Canada. The Meteorological Branch became the Atmospheric Environment Service in 1971 and so this instrument was probably manufactured before that date. Part of a large collection of meteorological instruments acquired from the Meteorological Service of Canada (previously Atmospheric Environment Service) by the CSTM since 1967. MSC is the government agency responsible for collecting and disseminating meteorological data and forecasts in Canada. It was founded in 1871 in Toronto where it is still headquartered. The MSC was originally on the University of Toronto downtown campus but moved to Downsview in 1971 on land owned by UofT. The headquarters houses laboratories, research facilities and calibration and instrument maintenance facilities (now largely contracted out). - Fonction
-
An instrument that measures atmospheric pressure and indicates the results in a digital format, used in the calibration of pressure measuring instruments. - Technique
-
This barometer was used in the MSC calibration laboratory and had a calibrated range of 13 - 15.5 A. It contains an oven used to maintain the aneroid at a fixed temperature. The barometer was connected via a tube on the back to a sealed plenum on which other barometers being calibrated were attached. By varying the volume the pressure could be varied and the barometers calibrated. This unit was not the standard but would have been used as a visual readout to monitor the pressure within the plenum. The standard was and is the dead weight tester, the Ruska 2465 gas piston gauge (Ref. 2). The portable version of Bell and Howell's 4-461 digital barometer, which uses a pressure-to-frequency transducer and digital electronics to produce a digital display that indicates directly the atmospheric pressure in millibars. The barometer consists of a digital pressure transducer and a front panel LED display. The pressure measurement is converted by the transducer to a variable frequency signal. This signal, the frequency of which varies with the pressure, is fed into a counter where it is converted into a digital data signal. The latter is sent to the front panel LED assembly, which produces a five digit display and to rear panel connector to be sent to a computer of a remote readout unit (Ref. 1). The pressure sensing element operates as follows: the pressure input to the barometer is applied to a bellows attached to a diaphragm. As the input varies, the diaphragm moves between the fixed plates of a capacitor, causing an increase in capacitance between one plate and the diaphragm and a corresponding decrease capacitance between the other plate and the diaphragm. This chance in capacitance causes a frequency deviation in each of two 50 MHz oscillators, causing one frequency to decrease and the other to increase by an equal amount. The two frequencies are fed into a mixer which produces a signal the frequency of which varies with the input pressure. A precisely controlled heater maintains a constant temperature within the sensor enclosure. The signal is fed to a digital counter that samples the output frequency of the sensor. The time period of the sample count is variable to provide readout in the desired units (Ref. 1). - Notes sur la région
-
Inconnu
Détails
- Marques
- black lettering on casing front reads 'digital barometer', 'CALIBRATED RANGE/ 13 to 15.5 A/ MILLIBARS' INSTRUMENTS DIVISION/ [logo] BELL & HOWELL'/ grey label on back reads '[logo] BELL & HOWELL/ Pasadena, California/ TYPE 4-461-0005 SERIAL 2180/ ASSEMBLY 368000-K'/ label on back reads ‘GOVERNMENT OF CANADA/ METEOROLOGICAL BRANCH/ INSTRUMENT DIVISION/ CALIBRATION UNIT/ C16-224 2180/ DEPARTMENT OF TRANSPORT'/ handwritten lettering on correction chart affixed to casing top reads in part ' #2180 JULY 3, 1985'/ inventory label on side reads in part 'JAN/84'
- Manque
- appears complete
- Fini
- medium blue painted casing/ black painted front casing frame and black and off-white synthetic front panel with black and red synthetic controls and indicator window/ grey power cord/ colourless transparent shield covering counters on back
- Décoration
- parallel horizontal grooves in front window frame
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
Bell & Howell, Baromètre, avant 1971, Numéro de l'artefact 2004.0366, Ingenium - Musées des sciences et de l'innovation du Canada, http://collection.ingeniumcanada.org/fr/id/2004.0366.001/
RÉTROACTION
Envoyer une question ou un commentaire sur cet artefact.