Température d'étalonnage
Utiliser cette image
Puis-je réutiliser cette image sans autorisation? Oui
Les images sur le portail de la collection d’Ingenium ont la licence Creative Commons suivante :
Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)
ATTRIBUER CETTE IMAGE
Ingenium,
2004.0314.001
Permalien:
Ingenium diffuse cette image sous le cadre de licence Creative Commons et encourage son téléchargement et sa réutilisation à des fins non commerciales. Veuillez mentionner Ingenium et citer le numéro de l’artefact.
TÉLÉCHARGER L’IMAGEACHETER CETTE IMAGE
Cette image peut être utilisée gratuitement pour des fins non commerciales.
Pour un usage commercial, veuillez consulter nos frais de reproduction et communiquer avec nous pour acheter l’image.
- TYPE D’OBJET
- mercury triple point
- DATE
- 1990
- NUMÉRO DE L’ARTEFACT
- 2004.0314.001
- FABRICANT
- YSI Inc.
- MODÈLE
- 17725
- EMPLACEMENT
- Yellow Springs, Ohio, United States of America
Plus d’information
Renseignements généraux
- Nº de série
- M8608
- Nº de partie
- 1
- Nombre total de parties
- 2
- Ou
- Mercury triple point temperature standard
- Brevets
- S/O
- Description générale
- metal casing, control panel, handles, parts/ synthetic knob, panel, power cord, parts/ rubber? corks
Dimensions
Remarque : Cette information reflète la taille générale pour l’entreposage et ne représente pas nécessairement les véritables dimensions de l’objet.
- Longueur
- 60,0 cm
- Largeur
- 49,0 cm
- Hauteur
- 98,0 cm
- Épaisseur
- S/O
- Poids
- S/O
- Diamètre
- S/O
- Volume
- S/O
Lexique
- Groupe
- Métrologie
- Catégorie
- Température
- Sous-catégorie
- S/O
Fabricant
- Ou
- YSI
- Pays
- United States of America
- État/province
- Ohio
- Ville
- Yellow Springs
Contexte
- Pays
- Canada
- État/province
- Ontario
- Période
- Inconnu
- Canada
-
Part of a large collection of meteorological instruments acquired from the Meteorological Service of Canada (previously Atmospheric Environment Service) by the CSTM since 1967. MSC is the government agency responsible for collecting and disseminating meteorological data and forecasts in Canada. It was founded in 1871 in Toronto where it is still headquartered. The MSC was originally on the University of Toronto downtown campus but moved to Downsview in 1971 on land owned by UofT. The headquarters houses laboratories, research facilities and calibration and instrument maintenance facilities (now largely contracted out). - Fonction
-
An instrument used in a meteorological instrument laboratory to calibrate thermometers. - Technique
-
An example of a temperature standard used in a laboratory for the calibration of meteorological thermometers. In 2006, both Isothermal Technology Ltd. of England and YSI Temperature of the U.S. still offered the model 17725 temperature standard and the 17725 mercury cell for sale (Ref. 1-2). A triple point is the temperature and pressure at which the gaseous, liquid and solid phases of a given substance coexist at equilibrium. The triple point of mercury is.-38.8344°C. at a pressure of 0.2 mPa. (Ref. 3-4) This apparatus is a free-standing, self-contained mechanically refrigerated cryostat. The mercury cell (2004.0324.2) is placed in its well, which is operated in the form of an essentially gradient-free heat pipe. A unique control system provides a precise means for regulation of the cell and well temperature over the range from -36 °C to -42 °C, allowing the mercury triple point to be approached optionally from the freezing or melting direction. Two auxiliary wells are pre-chilling thermometers to be calibrated. The cell containment is a plasma-arc welded stainless steel shell. The mercury contained has impurities of less than 15 parts per billion. The purity of the metals such that triple point plateaux are flat to 100 microkelvins (0.0001 °C) (Ref. 2). - Notes sur la région
-
Inconnu
Détails
- Marques
- incised black lettering on front plate reads 'YSI MODEL 17725/ MERCURY TRIPLE POINT/ TEMPERATURE STANDARD/ (Requires YSI Model 17724 Mercury Triple Point Cell)/ [logo reading YSI] YSI Incorporated/ Yellow Springs, Ohio 45387 USA'/ label on back reads 'YSI Incorporated YELLOW SPRINGS INSTRUMENT CORP. INC./ YELLOW SPRINGS, OHIO 45387-0279 USA/ Model 17725 Sn M8608/ V 110 A 15 Hz 60'/ black synthetic label on synthetic top panel reads '-38.84041/ ITS90 -38.8331'
- Manque
- unknown - appears complete
- Fini
- glossy dark grey painted casing/ brushed metal control panel plate on front with black synthetic knob and brushed metal handles/ textured grey synthetic panel on top with two black rubber corks/ black power cord
- Décoration
- S/O
FAIRE RÉFÉRENCE À CET OBJET
Si vous souhaitez publier de l’information sur cet objet de collection, veuillez indiquer ce qui suit :
YSI Inc., Température d'étalonnage, avant 1990, Numéro de l'artefact 2004.0314, Ingenium - Musées des sciences et de l'innovation du Canada, http://collection.ingeniumcanada.org/fr/item/2004.0314.001/
RÉTROACTION
Envoyer une question ou un commentaire sur cet artefact.