Suit part, anti-G

Use this image

Can I reuse this image without permission? Yes

Object images on the Ingenium Collection’s portal have the following Creative Commons license:

Copyright Ingenium / CC BY-NC-ND (Attribution-NonCommercial 4.0 International (CC BY-NC 4.0)

ATTRIBUTE THIS IMAGE

Ingenium, 2002.0613.005
Permalink:

Ingenium is releasing this image under the Creative Commons licensing framework, and encourages downloading and reuse for non-commercial purposes. Please acknowledge Ingenium and cite the artifact number.

DOWNLOAD IMAGE

PURCHASE THIS IMAGE

This image is free for non-commercial use.

For commercial use, please consult our Reproduction Fees and contact us to purchase the image.

OBJECT TYPE
limb/hydraulic
DATE
1939
ARTIFACT NUMBER
2002.0613.005
MANUFACTURER
University of Toronto
MODEL
F.F.S. III
LOCATION
Toronto, Ontario, Canada

More Information


General Information

Serial #
prototype 1
Part Number
5
Total Parts
10
AKA
right mitt
Patents
N/A
General Description
cotton [and possibly other] fabric components; metal zippers and eyelets; rubber bladders and tubing; synthetic tubing connectors

Dimensions

Note: These reflect the general size for storage and are not necessarily representative of the object's true dimensions.

Length
31.0 cm
Width
21.5 cm
Height
4.5 cm
Thickness
N/A
Weight
N/A
Diameter
N/A
Volume
N/A

Lexicon

Group
Aviation
Category
Clothing
Sub-Category
N/A

Manufacturer

AKA
University
Country
Canada
State/Province
Ontario
City
Toronto

Context

Country
Canada
State/Province
Ontario
Period
This model suit used c. 1939- early 1940 [possibly for testing purposes only]
Canada
Dr. W.R. Franks, Professor in Medical Research, University of Toronto was a leader in aviation research work conducted in Canada during the late 1930s-1940s on problems associated with acceleration. Among his accomplishments in the field, Franks developed an anti-G suit (the " F.F.S."] which applied pressure to the calves, thighs and abdomen to prevent pooling of the blood in the veins of these areas, and supported the increased pressure developed in the arterial bed of the same regions. This prevented blackouts and unconsciousness, and delayed the onset of fatigue- critical problems for pilots subjected to centrifugal force during aerial manoeuvrers. [Ref. 6] This [and other versions of the F.F.S.] required testing in a controlled and reproduceable environment. For this purpose, a "human centrifuge", the R.C.A.F. accelerator was designed and constructed. [see 1987.0229 and 1976.0529]. [Ref. 5]
Function
To prevent pooling of the blood in the veins of the abdomen and extremities.
Technical
The Mark III F.F.S. was the first anti-G suit to be used in actual air operations anywhere in the world. It demonstrated the value and practicality of anti-G suits, which lead to further development of the technology and later versions of the Franks suit. The first prototype suit was constructed of thin cotton and made to fit Franks himself . It was sewn together in Franks' office at the University of Toronto, and had thin rubber bladders vulcanized throughout, allowing the wearer's full body to be protected by a thin film of water. Franks wore the suit during testing in a Finch Fleet biplane. He realized that not all areas of the body required equal protection from G-forces, and modified his original prototype accordingly. This piece may be one of the elements of the refined prototype suit. [Ref. 6, p.114] The body part for which the piece was designed, and some elements of construction/finish are handwritten in black lead pencil on the exterior, suggesting it may also have served as a pattern, or provided instructions for assembly [by tailor ?].
Area Notes
Unknown

Details

Markings
UHN catalogue no. "978.8.27d" printed by hand in black ink on off-white cotton label sewn to upper edge of form.
Missing
One component of suit: piece is complete in itself.
Finish
Off-white cotton fabric and thread; gold tone metal zipper has drab-green colour woven fabric [cotton ?] facing; light and dark brown rubber tubing and brown synthetic tube connect mitt to .4 right forearm.
Decoration
N/A

CITE THIS OBJECT

If you choose to share our information about this collection object, please cite:

University of Toronto, Suit part, anti-G, circa 1939, Artifact no. 2002.0613, Ingenium – Canada’s Museums of Science and Innovation, http://collection.ingeniumcanada.org/en/id/2002.0613.005/

FEEDBACK

Submit a question or comment about this artifact.

More Like This


...
Suit part, an…

2002.0613.008

Object

...
Suit part, an…

2002.0613.007

Object

...
Suit part, an…

2002.0613.004

Object

...
Suit part, an…

2002.0613.009

Object

...
Suit part, an…

2002.0613.006

Object

...
Suit part, an…

2002.0613.003

Object

...
Suit part, an…

2002.0613.002

Object

...
Suit part, an…

2002.0613.001

Object

...
Bag, camera

2002.0613.010

Object

...
Suit, anti-G

2002.0608.001

Object

...
Suit, anti-G

2002.0612.001

Object

...
Suit, anti-G

2002.0609.001

Object

...
Suit, anti-G

2002.0610.001

Object

...
Centrifuge, h…

1987.0229.001

Object

...
Centrifuge mo…

1976.0529.001

Object

...
Human centrif…

1987.0230.001

Object

...
Suit, pressure

2002.0611.001

Object

...
Human centrif…

1987.0233.001

Object

...
Human centrif…

1987.0235.001

Object

...
Rectifier

1987.0234.001

Object

...
Starter, motor

1987.0236.001

Object

...
Suit, anti-G

2002.0615.001

Object

...
Relay

1987.0237.001

Object

...
Generator

1987.0232.001

Object

...
Motor

1987.0238.001

Object

...
Motor

1987.0231.001

Object

...
Suit, anti-G

1976.0607.001

Object

...
Suit, anti-G

1992.2313.001

Object

...
Suit, anti-G

1992.2312.001

Object

...
Suit, anti-G

1976.0608.001

Object

...
Suit, anti-G

1976.0609.001

Object

...
Bottle, stora…

2002.0730.001

Object

...
Artificial he…

2002.0553.001

Object

...
Artificial he…

2002.0552.001

Object

...
Carrier, test…

2002.0767.002

Object

No image available.
Collar, test …

2002.0767.003

Object

...
Cuff

2002.0712.002

Object

...
G Suit

CAVM-07167

Archives

...
Pump system

2002.0619.004

Object

...
Suit, beekeep…

2003.0006.001

Object

...
Exchanger, he…

2002.0566.001

Object

...
Coverall, fly…

2002.0616.001

Object

...
Cover

2002.0619.002

Object

No image available.
Cuff

2002.0714.002

Object

...
Centrifuge

1983.0098.001

Object

...
Fabric sample

1991.0022.001

Object

...
Oxygenator pa…

2002.0565.004

Object

...
Catheter

1978.1156.001

Object

...
Aspirator part

2002.0938.008

Object

...
Suit, diving

1972.0142.001

Object

...
Suit, flying

1990.0335.001

Object

...
Oxygenator

2002.0565.001

Object

...
Gasket

2002.0620.004

Object

...
Gasket

2002.0620.005

Object

...
Artificial ki…

2002.0620.001

Object

...
Carrier, test…

2002.0766.002

Object

...
Carrier, test…

2002.0766.003

Object

...
Suit, flying

1993.0377.001

Object

...
Lancet

1991.0007.001

Object

No image available.
Suit, flying

2006.0134.001

Object

...
Pump, dialysa…

2002.0620.002

Object

...
Suit, flying

1990.0342.001

Object

...
Vaccination k…

2002.0101.001

Object

...
Hemoglobinome…

1981.1702.001

Object

...
Case, storage…

2014.0300.006

Object

...
Centrifuge

2002.0767.001

Object

...
Coveralls

2003.0617.001

Object

...
Catheter

1978.1155.001

Object

...
Clamp, surgic…

2002.0981.001

Object

...
Oxygenator pa…

2002.0565.002

Object

...
Trousers, fly…

2002.0289.001

Object

...
Suit, flying

1971.0582.001

Object

...
Coveralls

2003.0619.001

Object

...
Heating pad

1992.0596.001

Object

...
Tubing

1983.0100.004

Object

...
Dialyzer

2002.0620.003

Object

...
Sphygmomanome…

2002.0213.001

Object

...
Motion machin…

2002.0493.001

Object

...
Pipette

2008.1612.003

Object

No image available.
Suit, flying

1993.0401.001

Object

...
Test set, vac…

1988.0250.001

Object

...
Oxygenator pa…

2002.0565.003

Object

...
Motor

1992.2103.001

Object

...
Motion machin…

2002.0492.001

Object

...
Oxygenator

2002.0622.001

Object

...
Receiver, rad…

2001.0218.001

Object

...
Colourimeter …

1993.0175.001

Object

...
Coveralls

1997.1094.001

Object

...
Breathing app…

2015.0120.002

Object

No image available.
Travel kit

2007.0165.001

Object

...
Bag, changing

2000.0123.001

Object

...
Coveralls

2016.0008.001

Object

...
Tubing

1981.1703.004

Object

...
Tubing

1981.1703.005

Object

...
Tube, connect…

2014.0036.002

Object

...
Coveralls

1987.0201.001

Object

...
Coveralls

1997.1093.001

Object

...
Coveralls

1997.1093.002

Object

...
Adjuster, foc…

1988.0105.001

Object

...
Container, sh…

2002.0730.002

Object